PRECISION DIGITAL CORPORATION 89 October Hill Road • Holliston MA 01746 USA Tel (800) 343-1001 • Fax (508) 655-8990 www.predig.com Strain Gauge, Loa
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 10 WEIGHT 9.5 oz (269 g) WARRANTY 3 years parts & labor Strain Gauge Input IN
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual LIM6100_B SFT039 Ver 3.200 & up 1/15 How to Contact Precision Digital For Te
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 11 DEADBAND 0-100% of span, user programmable HIGH OR LOW ALARM User may program a
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 12 NON-ISOLATED TRANSMITTER POWER SUPPLY Terminals I+ & R: 24 VDC 10% . May b
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 13 Electromagnetic Compatibility EMISSIONS EN 55022:2010 Class A ITE emissions requ
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 14 SAFETY INFORMATION CAUTION: Read complete instructions prior to inst
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 15 Figure 1. 1/8 DIN Panel Cutout Dimensions Figure 2. Panel Mounting Details P
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 16 Mounting Dimensions Figure 3. Meter Dimensions - Side View Figure 4. Meter
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 17 Configuration for 12 or 24 VDC Input Power Option Warning! Do not exceed volt
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 18 Sensor Excitation Voltage Selection (EX+, EX-) All meters, including models equi
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 19 Connectors Labeling The connectors’ label, affixed to the meter, shows the locat
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 2 Disclaimer The information contained in this document is subject to change withou
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 20 Signal Connections Signal connections are made to a six-terminal connector label
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 21 Range (Switch 2) The range switch adjusts the gain of the internal c
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 22 Shunt Resistor (Switch 5) The PD6100 provides a means of simulating s
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 23 NOTE: Refer to Switch Configuration starting on page 20 for proper switch positi
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 24 predetermined resistive load(60.4k). This technique can be used as a means of ve
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 25 Switching Inductive Loads The use of suppressors (snubbers) is strongly recommen
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 26 4-20 mA Output Connections Connections for the 4-20 mA transmitter output are ma
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 27 External Relays & Digital I/O Connections The relay and the digital I/O expa
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 28 Figure 21. Digital I/O Module Connections Interlock Relay Feature As the name
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 29 SETUP AND PROGRAMMING The meter is factory calibrated prior to shipment to read
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 3 Table of Contents INTRODUCTION --------------------------------------------------
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 30 Front Panel Buttons and Status LED Indicators Button Symbol Description LED St
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 31 Display Functions & Messages The meter displays various functions and messag
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 32 Display Parameter Action/Setting Description Cal Calibrate Enter the Calibration
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 33 Display Parameter Action/Setting Description RLY 2 Relay 2 Relays 2-8 setup Note
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 34 Contrl Control Enter Control menu Auto Automatic Press Enter to set meter for au
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 35 Main Menu The main menu consists of the most commonly used functions: Setup, Res
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 36 Setting Up the Meter (setup) The Setup menu is used to select: 1. Unipolar (e.g
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 37 Setting the Input Signal (Input) Enter the Input menu to set up the input polari
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 38 Input Polarity Selection (PoLAR) Select unipolar operation for inputs in ranges
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 39 Setting the Input Units (units) Enter the pre-defined engineering unit or custom
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 4 Setting Up the Meter (setup) ------------------------------------------------ 36
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 40 Setting the Input Units or Custom Tags (units) Enter the input unit or custom ta
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 41 Setting the Decimal Point (dEc pt) The decimal point may be set with up to five
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 42 Programming the Meter (prog) The Program menu contains the Scale and the Calibra
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 43 Calibrating the Meter with Strain Gauge/Load Cell (Cal) To scale the meter witho
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 44 MeterView® Pro Software The meter can also be programmed using the PC-based Mete
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 45 Dual-Scale Application The analog input can be displayed in two different scales
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 46 Error Message (Error) An error message indicates that the calibration or scaling
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 47 Setting the Display Parameter & Intensity (dsplay) The upper display (Big) c
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 48 Display Setup Menu
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 49 Setting the Relay Operation (relay) This menu is used to set up the operation of
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 5 Protecting or Locking the Meter ------------------------------------------- 68Ma
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 50 Setting the Relay Action Operation of the relays is programmed in the Action men
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 51 Programming Set and Reset Points High alarm indication: program set point above
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 52 Relay and Alarm Operation Diagrams The following graphs illustrate the operation
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 53 Low Alarm Operation (Set < Reset) For Manual reset mode, ACK can be pressed
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 54 High Alarm with Fail-Safe Operation (Set > Reset) Note: Relay coil is energ
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 55 Low Alarm with Fail-Safe Operation (Set < Reset) Note: Relay coil is energ
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 56 Pump Alternation Control Operation
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 57 Relay Sampling Operation When the signal crosses the set point, the relay trip
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 58 Time Delay Operation The following graphs show the operation of the time delay f
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 59 Relay Operation Details Overview The relay capabilities of the meter expand its
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 6 Table of Figures Figure 1. 1/8 DIN Panel Cutout Dimensions ...
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 60 Front Panel LEDs The LEDs on the front panel provide status indication for the f
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 61 Non-Latching Relay (Auto) Automatic reset only Condition LED RelayNormal Off Off
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 62 Latching Relay (Lt-Clr) Manual reset only after alarm condition has cleared Cond
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 63 Pump Alternation Control Applications (Altern) For pump control applications whe
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 64 Application #2: Pump Alternation Using Relays 3 & 4 1. Relays 1 and 2 are s
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 65 3. If the backup pump is not able to keep up, and the level reaches 7000 gallo
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 66 Setting Up the Interlock Relay (Force On) Feature Relays 1-4 can be set up as in
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 67 Scaling the 4-20 mA Analog Output (Aout) The 4-20 mA analog output can be scaled
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 68 Setting Up the Password (pass) The Password menu is used for programming three l
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 69 Making Changes to a Password Protected Meter If the meter is password protected,
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 7 ORDERING INFORMATION Standard Models 85-265 VAC Model 12/24 VDC Model Options Ins
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 70 Reset Menu (reset) The Reset menu is used to reset the tare (rst tr) and the max
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 71 Control Menu (Contrl) The Control menu is used to control the 4-20 mA analog out
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 72 Advanced Features Menu & Display Messages The following table shows the func
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 73 Display Parameter Action/Setting O-rang Overrange Program mA output for display
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 74 Display Parameter Action/Setting v Hi mV high Calibrate high mV input (e.g. 10
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 75 Noise Filter (filter) The noise filter is available for unusually noisy signals
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 76 Modbus RTU Serial Communications (serial) The meter is equipped with serial comm
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 77 Select Menu (SElect) The Select menu is used to select the signal input conditio
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 78 Multi-Point Linearization (Linear) Meters are set up at the factory for linear f
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 79 Low-Flow Cutoff (CutofF) The low-flow cutoff feature allows the meter to be prog
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 8 SPECIFICATIONS Except where noted all specifications apply to operation at +25°C.
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 80 Programmable Function Keys User Menu (user) The User menu allows the user to ass
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 81 Internal Source Calibration (ICAL) The meter is factory calibrated prior to ship
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 82 Example of Internal Calibration for 100 mV input range: 4. The meter displays t
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 83 Error Message (error) An error message indicates that the calibration or scaling
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 84 Meter Copy Function (Copy) The Copy function is used to copy (or clone) all the
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 85 METER OPERATION The meter is capable of accepting any signal from -250 to 250 mV
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 86 Maximum/Minimum Readings The max & min readings (peak & valley) reached
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 87 TROUBLESHOOTING Due to the many features and functions of the meter, it’s possib
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 88 Reset Meter to Factory Defaults When the parameters have been changed in a way t
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 89 Factory Defaults & User Settings The following table shows the factory setti
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 9 ISOLATED SENSOR POWER SUPPLY Terminals P+ & P-: 10 VDC or 5 VDC 10%.12/24 V
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 90 Parameter Display Default Setting User SettingRelay 2 action Act 2 Automatic R
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 91 Parameter Display Default Setting User SettingMinimum output min 1.000 mA Sl
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 92 Troubleshooting Tips (Including FAULT & ERROR Messages) Symptom Check/Action
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 93 Alphabetical List of Display Functions & Messages Display Parameter Action/
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 94 Display Parameter Action/Setting Description Big HL Max/min upper display Assign
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 95 Display Parameter Action/Setting Description Diag Diagnostics Display parameter
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 96 Display Parameter Action/Setting Description ICal Internal source calibration En
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 97 Display Parameter Action/Setting Description No PtS Number of points Set meter f
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 98 Display Parameter Action/Setting Description RLY 1 Relay 1 Relay 1 setup (1-8) R
Model PD6100 Strain Gauge/Load Cell Meter Instruction Manual 99 Display Parameter Action/Setting Description units Units Select the display unit