PD690 Universal Process Meter
Instruction Manual
PRECISION DIGITAL CORPORATION
89 October Hill Road • Holliston MA 01746 USA
Tel (800) 343-1001 • Fax (508) 655-8990
www.predig.com
Easy Single Button Scaling (SBS)
4-20 mA, 0-5 V, or 0-10 V Field Selectable Inputs
24 V Transmitter Power Supply Standard
Scale Without a Calibrator
Calibrate with a Signal Source
Steady, Accurate Display to ± 199,990
11-Point Linearization for Non-Linear Inputs
Square Root Extraction with Low-Flow Cutoff
41/2 Digit + Extra Zero
NEMA 4X, IP65 Front Panel
2 or 4 Relays + 4-20 mA Output Options
115 VAC, 230 VAC, or 24 VDC Power Options
Lockout Feature
Non-Volatile Memory, No Battery Needed
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - Instruction Manual

PD690 Universal Process Meter Instruction Manual PRECISION DIGITAL CORPORATION 89 October Hill Road • Holliston MA 01746 USA Tel (800) 343-1001 • Fa

Page 2

www.predig.comModel PD690 Universal Process Meter Instruction Manual10SETUP AND PROGRAMMINGPower, Signal, External Functions & Options Connections

Page 3

www.predig.comOverviewThe following field wiring connections are made to removable screwterminal blocks supplied with the meter: Power, Signal Input,

Page 4 - Typical Applications

www.predig.comModel PD690 Universal Process Meter Instruction ManualAC Powered Meters (Power, Signal, External Functions)Figure 2: Transmitter Powered

Page 5 - AVERTISSEMENT

www.predig.comModel PD690 Universal Process Meter Instruction Manual13AC Powered Meters (Continued)Figure 4: Three-Wire Transducer Powered from MeterF

Page 6 - Basic Meter

Model PD690 Universal Process Meter Instruction ManualDC Powered Meters (Power, Signal, External Functions)Figure 6: Transmitter and Meter Powered fro

Page 7 - 14 HP @

www.predig.comModel PD690 Universal Process Meter Instruction ManualRelays & 4-20 mA OutputDepending on the model number, the Options Board may co

Page 8

Model PD690 Universal Process Meter Instruction Manual4-20 mA Output The 4-20 mA output from the meter can either be powered from themeter’s internal

Page 9

Model PD690 Universal Process Meter Instruction Manual17ProgrammingOverviewThe meter is programmed using the ENTER button and three jumperarrays. The

Page 10 - SETUP AND PROGRAMMING

Figure 13: Two-point External Calibration Flow ChartModel PD690 Universal Process Meter Instruction Manual18www.predig.comCalibrationComplete!Push ENT

Page 11 - Wiring Instructions

www.predig.comModel PD690 Universal Process Meter Instruction Manual19Five Basic Digit/Display-setting InstructionsRather than repeat the Single Butto

Page 12

Model PD690 Universal Process Meter Instruction ManualINTRODUCTION ...

Page 13 - AC Powered Meters (Continued)

www.predig.comModel PD690 Universal Process Meter Instruction ManualSelect Input SignalThe meter can be programmed to accept current or voltage inputu

Page 14

www.predig.comModel PD690 Universal Process Meter Instruction Manual21Select Calibration MethodThe meter may be calibrated using an external signal so

Page 15 - Relays & 4-20 mA Output

Model PD690 Universal Process Meter Instruction Manual22www.predig.comGeneral Calibration/Scaling InstructionsCalibration is performed from the front

Page 16 - 4-20 mA Output

Model PD690 Universal Process Meter Instruction Manual23www.predig.comCalibrate Using an External Calibrator (E-[al)If E-[AL (External Calibration) wa

Page 17 - Single Button Scaling (SBS)

Model PD690 Universal Process Meter Instruction Manual24www.predig.comSelect Square Root Extraction (L or S)With the square root extraction function a

Page 18 - Complete!

Round Horizontal Tank Calibration TableThe following tables can be used to calibrate the meter for displayingvolume in a round horizontal tank. The r

Page 19 - Basic Meter Programming

Model PD690 Universal Process Meter Instruction Manual26www.predig.comIsolated 4-20 mA Transmitter Output Programming (ovtpvt)The Isolated 4-20 mA Tra

Page 20 - Select Input Signal

Model PD690 Universal Process Meter Instruction Manualwww.predig.comAlarm ProgrammingOverviewThe meter is equipped with four alarm points as a standar

Page 21 - Select Linear Input (L or S)

Programming ConfirmationTo verify that the alarm set and reset points have been programmedas desired, push ENTER, and push ENTER again when ALArSappea

Page 22

www.predig.comModel PD690 Universal Process Meter Instruction Manual29Alarm AcknowledgmentThe ACK button on the front panel resets the optional relays

Page 23 - Calibration Error (Error)

Model PD690 Universal Process Meter Instruction ManualSelect Square Root Extraction (L or S) ...24Program Low-Flow Cuto

Page 24 - Instructions

www.predig.comLockout JumperOnce the meter has been completely programmed, a lockout jumpercan be installed to restrict further modification to the me

Page 25

www.predig.comLow Voltage DC LoadsFigure 16: Low Voltage DC LoadsUse a diode with a reverse breakdown voltage two to three times thecircuit voltage an

Page 26 - Programming Confirmation

OPTIONS CARD REMOVAL & INSTALLATIONMeter options are installed at the factory. It is NOT necessary toremove the circuit boards from the case to di

Page 27 - Alarm Programming

Model PD690 Universal Process Meter Instruction ManualTo re-install the meter in its case:1. Fold the Options Board over the Main Board, grasp both bo

Page 28

34www.predig.comModel PD690 Universal Process Meter Instruction ManualPROGRAMMED PARAMETER SETTINGSUse the following table to record how your meter is

Page 29 - Alarm Acknowledgment

MODEL DESCRIPTIONPD118 MINIMUX®8 Point ScannerPD141AFO VIGILANTE®four Point Annunciator with First-OutPD202-253 Digital Pressure GaugesPD602 Dart Low-

Page 30 - AC & DC Loads

Model PD690 Universal Process Meter Instruction ManualLIM690_G 10//08 How to Contact Precision Digital • For Technical Support ple

Page 31 - Low Voltage DC Loads

Model PD690 Universal Process Meter Instruction ManualINTRODUCTIONThis meter is a high performance, easy to use, industrial-grade micro-processor-base

Page 32 - Retaining Screws and Washers

Model PD690 Universal Process Meter Instruction ManualSafety NoticeObserve all safety regulations. Electrical wiring should beperformed in accordance

Page 33 - MOUNTING DIMENSIONS

Model PD690 Universal Process Meter Instruction ManualSPECIFICATIONSExcept where noted all specifications apply to operation at +25ºCBasic MeterINPUTS

Page 34 - Calibration Point Values

Model PD690 Universal Process Meter Instruction Manual11-POINT Input Range Minimum Span LINEARIZATION Between Inputs4-20 mA(1.6 mA / (Number of points

Page 35 - (GeneralPurpose)

Model PD690 Universal Process Meter Instruction ManualRESET User Select:1. Automatically when input passes reset point.2. Automatically + Manually (vi

Page 36 - LIM690_G

www.predig.comModel PD690 Universal Process Meter Instruction Manual9Display Messages and Functions The following table describes the various messages